LIVING ROOM:
- Largest Briza 22 Unit
- Installed high in kitchen wall near perpendicular living room wall
- Serves very large living room space with 11 ft ceilings
- mounted on wall
- Supply is ducted to vent 8 feet away through two side-by-side oval ducts.
- Return is unducted "plenum return" - will be inside an upper cabinet - cabinet will need a vent on the front or side
KITCHEN
- Large Briza 22 Unit
- Serves very large kitchen space with 11 ft ceilings
- mounted on wall
- Supply is ducted to vent in living room 4 feet away through two side-by-side ducts (one is round, one is oval).
- Return is unducted plenum return - will be inside an upper cabinet - cabinet will need a vent on the front or side
2nd FLOOR OFFICE
- Briza 12 unit - one of the smallest
- Installed in ceiling
- Serves small office
- Unit not visible - behind sheetrock
- Width of Supply is 22"
- Supply is 90 degree to ceiling below
- Return will be 90 degree to ceiling below
GUEST BATH - Serves 2nd Fl Guest Bedroom
- Briza 12
- Mounted in Guest Bath ceiling
- Supplies Guest Bedroom
- Unit not currently visible
- Supply is ducted 24" straight through adjacent wall
PRIMARY BR
- Briza 22
- Mounted in closet ceiling abutting Bedroom
- Supplies 2 spaces:
- vents directly through wall into Bedroom (larger vent)
- ducted 5 feet into adjacent bathroom ceiling vent (smaller vent)
- Return is "plenum" return - i.e., draws air from inside the ceiling cavity - we will install a return grille in a nearby wall
3rd FLOOR BEDROOMS AND LOUNGE
- Mounted in 3rd Floor Bathroom ceiling
- Supplies 1 small bedroom, 1 medium bedroom and a larger lounge space
- supplies small and medium bedrooms and lounge through a single duct running 4 feet to small ceiling vent in medium bedroom, another 1 foot to larger vent in lounge wall and another 8 feet to small ceiling vent in small bedroom
- Return is "plenum" return - i.e., draws air from inside the ceiling cavity - we will install a return grille in a nearby wall
3rd FLOOR OFFICE
- Briza 12 unit
- Installed in ceiling
- Serves small office with 9.5' ceilings
- Unit not visible - behind sheetrock except for a small hole for access to electrical outlet in ceiling
- Width of Supply is 35"
- Supply is 90 degree to ceiling below
- Return will be 90 degree to ceiling below
3rd FLOOR FRONT BEDROOM
- Briza 22
- Mounted in closet ceiling abutting Bedroom
- Supplies bedroom directly through wall
- Return is "plenum" return - i.e., draws air from inside the ceiling cavity - we will install a return grille in a nearby wall
- We need to install a panel in the ceiling underneath this unit as well as one on the wall behind it so that the filter can be removed.